KCD0-RSH-1.1D.4倍加福KFU8-DW-1.D KFU8-DW-1.D Rotation Speed Monitor Speed monitoring up to 40 kHz, 1 pre-select value with relay output and LED indicator, 2-, 3-, 4-wire and NAMUR sensors as well as rotary encoder connectable, Start-up delay, Menu driven operation via 4 front keys, Period measurement, Output ** can be inverted, Display devices can be set between 0.1 ... 2.5 sec. KFD2-DWB-1.D Rotation Speed Monitor 1-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Input frequency 1 mHz ... 12 kHz, 2 relay contact outputs, Start-up override, Configurable by keypad, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511 KFD2-UFC-1.D Frequency Converter with Trip Values 1-channel ** conditioner, 24 V DC supply (Power Rail), Input for 2- or 3-wire sensors, NAMUR sensors or dry contacts, Input frequency 1 mHz ... 10 kHz, Current output 0/4 mA ... 20 mA, Relay contact and transistor output, Start-up override, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511 KFU8-DWB-1.D Rotation Speed Monitor 1-channel ** conditioner, Universal usage at different power supplies, Dry contact or NAMUR inputs, Input frequency 1 mHz ... 12 kHz, 2 relay contact outputs, Start-up override, Configurable by keypad, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511, Rated voltage: 20 ... 90 V DC / 48 ... 253 V AC 50 ... 60 Hz KFU8-UFC-1.D Frequency Converter with Trip Values 1-channel ** conditioner, Universal usage at different power supplies, Input for 2- or 3-wire sensors, NAMUR sensors or dry contacts, Input frequency 1 mHz ... 10 kHz, Current output 0/4 mA ... 20 mA, Relay contact and transistor output, Start-up override, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511 KFU8-UFT-2.D Frequency Converter with Direction and Synchronization Monitor 2-channel ** conditioner, Universal usage at different power supplies, Dry contact or NAMUR inputs, Input frequency 1 mHz ... 1 kHz, Current output 0/4 mA ... 20 mA, Relay contact and transistor output, Start-up override, Configurable by PACTware or keypad, Line fault detection (LFD) KFD0-RSH-1.4S.PS2 Relay Module 1-channel ** conditioner, 24 V DC supply (loop powered), Logic input 20 V DC ... 26.5 V DC, non-polarized, Fail-safe relay contact output for de-energized and energized to safe function , Test pulse immunity, Up to SIL 3 acc. to IEC 61508 KFD2-RSH-1.2D.FL2 Relay Module 1-channel ** conditioner, 24 V DC supply, Logic input 19 V DC ... 26.4 V DC, Recommended connectable voltage 8 V DC ... 60 V DC, Relay contact output for de-energized to safe function, Line fault transparency (LFT), Diagnostic function, Up to SIL 3 acc. to IEC 61508, Up to PL e acc. to EN/ISO 13849 KFD2-RSH-1.2D.FL3 Relay Module 1-channel ** conditioner, 24 V DC supply, Logic input 19 V DC ... 26.4 V DC, Recommended connectable voltage 50 V AC ... 230 V AC, 60 V DC ... 110 V DC, Relay contact output for de-energized to safe function, Line fault transparency (LFT), Diagnostic function, Up to SIL 3 acc. to IEC 61508, Up to PL e acc. to EN/ISO 13849 KFD2-RSH-1.2E.L2 Relay Module 1-channel ** conditioner, 24 V DC supply, Logic input 19 V DC ... 26.4 V DC, Recommended connectable voltage 8 V DC ... 60 V DC, Relay contact output for energized to safe function , Line fault transparency (LFT), Diagnostic function, Up to SIL 3 acc. to IEC 61508 KFD2-RSH-1.2E.L3 Relay Module 1-channel ** conditioner, 24 V DC supply, Logic input 19 V DC ... 26.4 V DC, Recommended connectable voltage 50 V AC ... 230 V AC, 60 V DC ... 110 V DC, Relay contact output for energized to safe function , Line fault transparency (LFT), Diagnostic function, Up to SIL 3 acc. to IEC 61508 KCD0-RSH-1.1D.1 Relay Module 1-channel ** conditioner, 24 V DC supply (loop powered), Logic input 19 V DC ... 26.5 V DC, non-polarized, Relay contact output for de-energized to safe function, Test pulse immunity, Up to SIL 3 acc. to IEC 61508, Up to PL e acc. to EN/ISO 13849 KCD0-RSH-1.1D.4 Relay Module 1-channel ** conditioner, 24 V DC supply (loop powered), Logic input 19 V DC ... 26.5 V DC, non-polarized, Relay contact output for de-energized to safe function, Test pulse immunity, Up to SIL 3 acc. to IEC 61508, Up to PL e acc. to EN/ISO 13849 KCD0-RSH-1.1E.1 Relay Module 1-channel ** conditioner, 24 V DC supply (loop powered), Logic input 19 V DC ... 26.5 V DC, non-polarized, Relay contact output for energized to safe function , Test pulse immunity, Up to SIL 3 acc. to IEC 61508 KFD0-RO-2 Relay Module 2-channel ** conditioner, 24 V DC supply (loop powered), Logic input 15 V DC ... 30 V DC, non-polarized, Relay contact output, Up to SIL 3 acc. to IEC 61508 KFD0-RSH-1.1D.F1 Relay Module 1-channel ** conditioner, 24 V DC supply (loop powered), Logic input 19 V DC ... 26.5 V DC, non-polarized, Relay contact output for de-energized to safe function, Test pulse immunity, Up to SIL 3 acc. to IEC 61508, Up to PL e acc. to EN/ISO 13849 KFD2-STC5-1 SMART Transmitter Power Supply 1-channel ** conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA current sink/current source, Terminals with test points, Up to SIL 2 acc. to IEC 61508 KFD2-STC5-1.2O SMART Transmitter Power Supply 1-channel ** conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA, current sink/current source, Terminals with test points, Up to SIL 3 acc. to IEC 61508 KCD2-STC-1.2O SMART Transmitter Power Supply 1-channel ** conditioner, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA or 0/1 V ... 5 V, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508 KFD2-CRG2-1.D Transmitter Power Supply 1-channel ** conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA ... 20 mA, 2 relay contact outputs, Adjustable energized/de-energized delay, Programmable high/low alarm, Linearization function (max 20 points), Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511 KFD2-STC5-2 SMART Transmitter Power Supply 2-channel ** conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA current sink/current source, Terminals with test points, Up to SIL 2 acc. to IEC 61508 KFU8-CRG2-1.D Transmitter Power Supply 1-channel ** conditioner, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA ... 20 mA, 2 relay contact outputs, Adjustable energized/de-energized delay, Programmable high/low alarm, Linearization function (max 20 points), Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511 KFU8-VCR-1 Transmitter Power Supply/Converter 1-channel ** conditioner, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters, current and voltage sources, Current and voltage output, Rated voltage: 19 ... 90 V DC / 48 ... 253 V AC KCD2-STC-1 SMART Transmitter Power Supply 1-channel ** conditioner, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Sink or source mode, Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508 KCD2-STC-1.SP SMART Transmitter Power Supply 1-channel ** conditioner, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Sink or source mode, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508 KFD0-RSH-1.1E.1 Relay Module 1-channel ** conditioner, 24 V DC supply (loop powered), Logic input 19 V DC ... 26.5 V DC, non-polarized, Relay contact output for energized to safe function , Test pulse immunity, Up to SIL 3 acc. to IEC 61508 KFD0-RSH-1 Relay Module 1-channel ** conditioner, 24 V DC supply (loop powered), Logic input 16 V DC ... 30 V DC, non-polarized, Fail-safe relay contact output, Up to SIL 3 acc. to IEC 61508 KFD0-RSH-1-Y2 Relay Module 1-channel ** conditioner, 24 V DC supply (loop powered), Logic input 20 V DC ... 30 V DC, non-polarized, Fail-safe relay contact output, Test pulse immunity, Up to SIL 3 acc. to IEC 61508 KFD2-SL-4 Solenoid Driver, Power Amplifier 4-channel ** conditioner, 24 V DC supply (Power Rail), Output 600 mA per channel, Logic inputs, Common safety-oriented disable input, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Output rated operating current: 600 mA per channel , sustained short-circuit proof and overload-proof KFD2-SR2-2.W.SM Standstill and Rotational Direction Monitor 2-channel ** conditioner, 24 V DC supply, PNP/push-pull, dry contacts or NAMUR inputs, Selectable frequency trip values, 2 relay contact outputs, Start-up override, Selectable mode of operation, Without line fault detection, Up to SIL 2 acc. to IEC 61508 KFD2-UFT-2.D Frequency Converter with Direction and Synchronization Monitor 2-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Input frequency 1 mHz ... 1 kHz, Current output 0/4 mA ... 20 mA, Relay contact and transistor output, Start-up override, Configurable by PACTware or keypad, Line fault detection (LFD) KFU8-UFC-1.D.FA Frequency Converter with Trip Values 1-channel ** conditioner, Universal usage at different power supplies, Input for 2- or 3-wire sensors, NAMUR sensors or dry contacts, Input frequency 1 mHz ... 10 kHz, Current output 0/4 mA ... 20 mA, Relay contact and transistor output, Start-up override, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511
詞條
詞條說明
USB-FBPS-1.11.45.NI USB現(xiàn)場總線電源 USB現(xiàn)場總線電源,輸出:小值11 V / 45 mA,用于1 ... 2設(shè)備/測試設(shè)置,與NI PCMCIA-FBUS卡配合使用,允許用于2區(qū)操作,對(duì)于基金會(huì)現(xiàn)場總線H1 HD2-FBPS-1.500 現(xiàn)場總線電源集線器,電源模塊 輸出:28 ... 30 V / 500 mA,高功率干線,用于增加設(shè)備數(shù)量和延長電纜長度,帶電隔離,
Rosemount? 3144P 溫度變送器 Rosemount 3144P 溫度變送器為您提供具有行業(yè)性、穩(wěn)定性和性的溫度測量。變送器擁有雙腔外殼,能夠確保性和診斷,您的測量點(diǎn)正常運(yùn)行。這款變送器組合了 Rosemount X-well? 技術(shù)與羅斯蒙特 0085 管夾傳感器,可提供過程溫度的測量,免除對(duì)熱套管或過程滲透的需要 Rosemount? 3051 Copl
Rosemount? 1057 三通道變送器 1057 三輸入分析儀為傳感器提供 pH/ORP/ISE 或連接傳導(dǎo)率/電阻率輸入。借助不受限的雙測量選擇,您可以降低每次循環(huán)的成本同時(shí)節(jié)約面板空間 規(guī)格 外殼防護(hù)等級(jí) 聚碳酸酯。NEMA 4X/CSA 4 型 (IP65) 認(rèn)證 CSA: I 類,2 分類,A、B、C 和 D 組 Il 類,2 分類,E、F 和 G 組 Ill 類 T4A 環(huán)境溫度=
Rosemount?3900通用pH/ORP傳感器,含Variopol(VP)連接件 rosemount 3900 and 3900vp sensor Rosemount?3900通用pH/ORP傳感器 rosemount 398 and 398vp sensor Rosemount?389VP通用pH/ORP傳感器 rosemount 398 and 398vp sensor Rosemount
公司名: 上海創(chuàng)弗實(shí)業(yè)有限公司
聯(lián)系人: 張曉龍
電 話: 18001664790
手 機(jī): 18001664790
微 信: 18001664790
地 址: 上海松江方松辰塔路2號(hào)
郵 編:
網(wǎng) 址: chuangfusy.b2b168.com
公司名: 上海創(chuàng)弗實(shí)業(yè)有限公司
聯(lián)系人: 張曉龍
手 機(jī): 18001664790
電 話: 18001664790
地 址: 上海松江方松辰塔路2號(hào)
郵 編:
網(wǎng) 址: chuangfusy.b2b168.com