The SIMATIC Drive Controller is a drive-based controller in the SIMATIC S7-1500 range.
A SIMATIC Drive Controller combines the following functionalities in a SINAMICS S120 Booksize Compact housing:
Fail-safe SIMATIC S7-1500 technology CPU with integrated technology I/Os
SINAMICS S120 drive control
The two components are referred to as "CPU" and "SINAMICS Integrated" in this documentation.
The integrated SINAMICS S120 drive control is based on a CU320-2 Control Unit. It can control
a maximum of 6 servo drives,
a maximum of 6 drives with vector control, or
a maximum of 12 drives with U/f control
Fail-safe technology CPUs are available in two performance classes. Safety Integrated on the CPU side and drive side allows use in fail-safe applications.
The SIMATIC Drive Controller supports PROFINET and PROFIBUS DP communication.
As a component of the SINAMICS S120 drive system, the configuration conditions and rules of SINAMICS S120 apply to the SIMATIC Drive Controller.
The SIMATIC Drive Controller is optimized for automation solutions with motion control in which SINAMICS S120 high-performance converters are used.
With its extensive field bus interfaces, the SIMATIC Drive Controller is ideal for modular machine concepts.
The SIMATIC Drive Controller does not have an integrated display. You can alternatively run service functions over the integrated Web server, for example. You can save the service data to the SIMATIC memory card using the FUNCT button.
The SIMATIC Drive Controller has no S7-1500 backplane bus. You can connect S7-1500 I/O modules using the ET 200MP distributed I/O system. Note that CM/CP communication modules for PROFINET/PROFIBUS in particular cannot be used in the ET 200MP distributed I/O system. Only communication modules for point-to-point connection (CM PtP) can be used. Alternatively, other I/O systems are available for installation in the control cabinet (e.g. ET 200SP) or for cabinet-free installation (e.g. ET 200pro, ET 200AL and ET 200eco PN).
The function blocks for the use of time-based IO (TIO instructions) are not supported by the digital inputs/outputs of the X142 interface. Recommendation: Use the measuring input, output cam or cam track technology objects for the timer DI/DQ.
The SIMATIC Drive Controller supports replacement of the SIMATIC Drive Controller CPU with the modular SIMATIC S7-1500 CPUs. Replacement with controllers of other designs (e.g. ET 200SP, ET 200pro) is not possible.
The drive control integrated in the SIMATIC Drive Controller supports only functions that are relevant in the control context (i.e. functional subset of SINAMICS S120 CU320-2 functions). For example, the Drive Control Chart (DCC) and basic positioner (EPOS) functions are not supported by SINAMICS Integrated.
A complete overview of the functional subset compared with the S7-1500 automation system can be found in the S7-1500 Drive Controller system manual.
An exchange of devices between SINAMICS Integrated and SINAMICS S120 CU320-2 is not possible.
Copying and pasting of individual drive objects from SINAMICS Integrated to SINAMICS S120 CU320-2 (and vice versa) is not possible with V16.
詞條
詞條說(shuō)明
報(bào)告系統(tǒng)錯(cuò)誤原則上,可以移植使用 SIMATIC STEP 7 創(chuàng)建的系統(tǒng)錯(cuò)誤消息。限制在移植“報(bào)告系統(tǒng)錯(cuò)誤”(Report system errors) 應(yīng)用程序時(shí),僅會(huì)移植用戶(hù)在 SIMATIC STEP 7 項(xiàng)目中進(jìn)行的設(shè)置(例如,基本設(shè)置、塊編號(hào)、塊名等)。不會(huì)移植以下元素:SFM 塊SFM 消息和為組態(tài)消息文本而進(jìn)行的設(shè)置系統(tǒng)文本庫(kù)移植之后,可以手動(dòng)方式再次調(diào)整設(shè)置。 在**次編譯硬件組
未*的連接工業(yè)以太網(wǎng)中未*的連接與目前未知設(shè)備(例如診斷設(shè)備)的連接被組態(tài)為“未*”連接。如以下 ISO-on-TCP 連接的示例所述,可以通過(guò)不同的方式使用未*的連接;在 ISO 傳輸或 TCP 連接上,該過(guò)程與之類(lèi)似。聲明通信準(zhǔn)備就緒 - 被動(dòng)建立連接必須將連接建立設(shè)置為“被動(dòng)”。下列設(shè)置將應(yīng)用到 ISO-on-TCP 連接的地址設(shè)置中:遠(yuǎn)程 IP 地址和遠(yuǎn)程 TSAP 為空。即,它們
移植“ATT: 將值添加到表格中”的示例表格指令的移植過(guò)程(移植類(lèi)別 4)“表格指令”組中的指令在 S7-1500 中不再可用,而且無(wú)法在移植過(guò)程中使用其它指令進(jìn)行替代,因?yàn)檫@些指令都基于**尋址。 但是,S7-1500 中提供有可手動(dòng)實(shí)現(xiàn)這些指令的其它函數(shù)。 以下以指令“ATT: 將值添加到表格中”為例,說(shuō)明如何實(shí)現(xiàn)該函數(shù)功能。實(shí)現(xiàn)以下 SCL 程序中說(shuō)明了如何實(shí)現(xiàn)“ATT”指令。 本示例中的函
TIA Portal Teamcenter Gateway 的系統(tǒng)要求
TIA Portal Teamcenter Gateway 的系統(tǒng)要求系統(tǒng)要求使用 TIA Portal Teamcenter Gateway V14 的軟硬件要求與 TIA Portal V14 的相同。提示使用 TIA Portal Teamcenter Gateway 時(shí),要求所安裝軟件產(chǎn)品的版本相同要使用 TIA Portal Teamcenter Gateway 而無(wú)任何限制條件,所安裝
公司名: 上海騰希電氣技術(shù)有限公司
聯(lián)系人: 田禮科
電 話(huà): 021-37660026
手 機(jī): 13681875601
微 信: 13681875601
地 址: 上海松江上海市松江區(qū)廣富林路4855弄星月大業(yè)**88號(hào)4樓
郵 編:
網(wǎng) 址: shtxjd.cn.b2b168.com
公司名: 上海騰希電氣技術(shù)有限公司
聯(lián)系人: 田禮科
手 機(jī): 13681875601
電 話(huà): 021-37660026
地 址: 上海松江上海市松江區(qū)廣富林路4855弄星月大業(yè)**88號(hào)4樓
郵 編:
網(wǎng) 址: shtxjd.cn.b2b168.com