Proceed as follows to create a new project in the TIA Portal and add a SIMATIC Drive Controller:
Start TIA Portal.
Select the action "Start" > "Create new project" in the portal view.
Assign a name for the new project under "Project name".
Set the storage location with the "..." button.
If required, enter comments in the Comment field.
Click the "Create" button to create the project.
You have created the project and are currently in the portal view. To continue with the configuration, switch to the project view.
Select "Add new device" in the project tree.
In the "Add new device" dialog, select the device version you are using under "Controller" > "SIMATIC Drive Controller" and the firmware version of the device under "Version".
You use the "Open device view" checkbox to specify whether the hardware configuration view is to be opened once the device has been created. Keep the checkbox selected if you want to configure the CPU next.
Click OK to confirm the new device.
You have added the SIMATIC Drive Controller to the project and can now continue with configuration, parameter assignment and programming.
When you add a SIMATIC Drive Controller to the project, by default:
A "Drive Controller_a" group is generated
Two devices are added to the group, for example:
- PLC_b [CPU 1504D TF] and
- Integrated_c [S120, CPU 150xD]
圖片: SIMATIC Drive Controller in the project tree, device collapsed
SINAMICS Integrated is only created if Startdrive is installed. Both devices have already been joined in a network over the PROFIdrive Integrated_d subnet.
The respective instance numbers (a, b, c, d) are assigned by STEP 7 depending on the objects already present in the project.
圖片: SIMATIC Drive Controller network view
CPU (e.g. PLC_1) and integrated drive control (e.g. Integrated_1) are modeled as separate devices. You can also move the devices as required to other groups and delete the "Drive Controller" group. You can also add other devices to the "Drive Controller" group, for example a CU320-2 PN, if you require more than six servo drives.
提示 Adding SIMATIC Drive Controller directly to groupYou can add the SIMATIC Drive Controller directly to a group folder in the project tree even if the group folder is a subfolder: Select the required group. Go to the menu bar or shortcut menu and select "Add" > "Device". |
The CPU and SINAMICS Integrated are by default created in a shared group folder in the project tree.
To change this behavior, activate or deactivate the relevant options for the SIMATIC Drive Controller under "Settings" -> "Hardware configuration" -> "Device-specific settings".
圖片: Creation options for creating a SIMATIC Drive Controller
The table below sets out the benefits of configuration with or without grouping.
列表: Guide to groupingProjectGrouping
With "Drive Controller" grouping | Without grouping or user-specific grouping |
---|---|
Actions apply to all devices in a group, for example - Go online - Load to/from device - Copy You can add additional devices to the group as required, for example - with CU320-2 - with I/O system | Greater flexibility in project structure in the project tree, for example - by machine/plant modules - by CPUs and drives, in separate groups |
If you want to create the SIMATIC Drive Controller without the integrated drive, deselect the "Including SINAMICS Integrated" option.
Deselecting this option can, for example, be useful in the following cases:
You are copying a previously configured SINAMICS Integrated drive control from another project.
The project is to be processed by another user without SINAMICS Startdrive.
SINAMICS Integrated is not to be configured until later.
SINAMICS Integrated is not being used, for example, because another drive system is being used.
For the "Drive Controller" group, you have a range of functions to choose from in the menu bar, toolbar and shortcut menu. With "Go online", for example, you can go online with all devices in the group.
The functionality supported by a given device depends on the device and state. For example, the function "Download to device" is supported by the SINAMICS Integrated but not by the CPU when there is an active online connection. The "Load preview" dialog provides relevant information and suggestions for actions for loading.
圖片: Load preview
Requirements: STEP 7 Professional and SINAMICS Startdrive are installed.
Proceed as follows if your project only contains the CPU of a SIMATIC Drive Controller and you want to configure the missing SINAMICS Integrated.
Select "Add new device" in the project tree.
In the "Add new device" dialog, go to "Drives" > "Drives & starters" > "SINAMICS drives" > "SINAMICS S120 Integrated for SIMATIC" and select SINAMICS Integrated, and select the firmware version of the device under "Version".
Click OK to confirm.
Result: SINAMICS Integrated has been added to the project tree and can be networked with the CPU.
Requirements: STEP 7 Professional and SINAMICS Startdrive are installed.
Proceed as follows if your project only contains a SINAMICS Integrated of a SIMATIC Drive Controller and you want to configure the missing CPU.
To ensure that only the CPU (without SINAMICS Integrated) is created, deselect the "Including SINAMICS Integrated" option under "Settings" > "Hardware configuration" > "Device-specific settings". Also deselect the "With Drive Controller group folder" option if you do not want a group folder to be created. Alternatively, you will need to delete the components you do not require.
Select "Add new device" in the project tree.
In the "Add new device" dialog, select the relevant device version under "Controller" > "SIMATIC Drive Controller" and the firmware version of the device under "Version".
Click OK to confirm.
Result: The CPU has been added to the project tree and can be connected to the SINAMICS Integrated .
The following section explains how to replace a SIMATIC S7-1500 CPU with a SIMATIC Drive Controller in an existing project or vice versa.
Select the device to be replaced in the project tree and right-click to open the shortcut menu.
Select the "Replace device..." option
Select the module you want to use in the right-hand column. The "Compatibility information" section indicates whether the devices to be replaced are compatible and whether or not and, if so, which configurations will be lost in the process.
Click "OK" to confirm.
When replacing devices, remember that the SIMATIC Drive Controller consists of two networked devices – a CPU and a SINAMICS Integrated.
If you replace a modular SIMATIC S7-1500 CPU with a SIMATIC Drive Controller, the configurations at the integrated PROFINET interfaces and at the integrated PROFIBUS interface are retained. In other words, the interfaces are mapped to an interface of the same type.
Configurations of the onboard I/O of S7-1500 compact CPUs are not applied. Please also note the compatibility information in the device replacement dialog.
The centralized I/O in the S7-1500 automation system is moved to the "unplugged modules" area. If required, copy the I/O to a distributed I/O ET 200MP system before device replacement.
A connected SINAMICS S120 CU320-2 remains connected – it is not swapped out for a SINAMICS Integrated. If you require a SINAMICS Integrated, you need to create it manually.
For the device replacement, PROFIdrive Integrated is removed and SINAMICS Integrated remains as a non-networked device in the project. You can connect SINAMICS Integrated to a SIMATIC Drive Controller CPU again at a later time.
If you no longer need SINAMICS Integrated, manually delete it from the configuration.
Configurations at interface X142 are not applied.
提示 Device replacement with other CPU classes (for example ET 200SP CPUs or ET 200pro CPUs) is not possible. |
Device replacement is currently not supported
詞條
詞條說明
移植西班牙語文本 (WinCC V7)西班牙語文本的移植方式取決于相應的排序。針對傳統(tǒng)排序和**排序移植文本如果 WinCC V7 項目包含西班牙語(傳統(tǒng)排序)文本,則這些文本將被移植為西班牙語(西班牙)。如果 WinCC V7 項目包含西班牙語(**)文本,則這些文本將被移植為西班牙語(西班牙)。如果 WinCC V7 項目包含西班牙語(**排序)以及西班牙語(傳統(tǒng)排序)文本,則僅西班牙語(傳統(tǒng)
PingIP 網(wǎng)絡(luò)中地址的可達性提示只有與設(shè)備存在在線連接時才顯示該頁面。通過 ping 功能,可檢查特定地址在網(wǎng)絡(luò)中是否可到達。說明該頁面包含以下框:目標地址 (Dest. address)輸入設(shè)備的 IPV4、IPv6 地址或 FQDN(完全限定域名)。重復 (Repeat)輸入 ping 請求的數(shù)量。DNS 分辨率 (DNS Resolution)選擇要用于解析已輸入 FQDN 的 IP 地
S7-1200對V90 PN進行位置控制的三種方法S7-1200系列PLC通過PROFINET與V90 PN伺服驅(qū)動器搭配進行位置控制,實現(xiàn)的方法主要有以下三種:? 方法一、在PLC中組態(tài)位置軸工藝對象,V90使用標準報文3,通過MC_Power、MC_MoveAbsolute等PLC Open標準程序塊進行控制, 這種控制方式屬于中央控制方式(位置控制在PLC中計算,驅(qū)動執(zhí)行速度控制)。? 方法
在項目中搜索的設(shè)置概覽概述在下表中,列出了在項目中搜索的各種設(shè)置:組設(shè)置說明在項目中搜索激活“在項目中搜索”啟用或禁用在項目中搜索功能。重新創(chuàng)建搜索索引在項目中,重新生成搜索的搜索索引。
公司名: 上海騰希電氣技術(shù)有限公司
聯(lián)系人: 田禮科
電 話: 021-37660026
手 機: 13681875601
微 信: 13681875601
地 址: 上海松江上海市松江區(qū)廣富林路4855弄星月大業(yè)**88號4樓
郵 編:
網(wǎng) 址: shtxjd.cn.b2b168.com
公司名: 上海騰希電氣技術(shù)有限公司
聯(lián)系人: 田禮科
手 機: 13681875601
電 話: 021-37660026
地 址: 上海松江上海市松江區(qū)廣富林路4855弄星月大業(yè)**88號4樓
郵 編:
網(wǎng) 址: shtxjd.cn.b2b168.com