Timer DQ operating mode allows you to output up to two edges per application cycle (for example OB 91, OB 6x) at a specific time, for example, for use as a cam output.
Select the Timer DQ operating mode for the required channel.
圖片: Mode of operation: Timer DQ
You can invert the 24 V ** to adjust it to your process. By default, the ** is not inverted.
If you select the high-speed output option, the digital output is switched alternately to 24 V DC and ground.
Advantages of the high-speed output:
Extremely steep edges (output delay in the 1 μs range)
Extremely high switching frequencies
Maximum switching precision, for example, for use as a cam output
The output cam technology object must always be assigned to another technology object whose position is evaluated.
You can assign the output cam technology object to the following technology objects:
Synchronous axis
Positioning axis
External encoder
You can assign exactly one axis or one external encoder to the output cam.
You can assign multiple output cams to one axis or one external encoder.
Select the configuration of the output cam in the Technology objects folder in the project tree.
Configure the basic properties of the technology object in the Basic parameters configuration window.
圖片: Basic parameters
Define the name of the output cam in this field. The technology object is listed under this name in the project tree. The tags of the output cam can be used in the user program under this name.
STEP 7 displays the axis or external encoder assigned to the output cam. You can use the link to directly access the basic parameters of the higher-level technology object.
Select an output cam type on the basis of the required switching behavior:
Position-based cam (position-dependent switch-on/switch-off)
Time-based cam (position-dependent switch-on and position-independent or time-dependent switch-off)
In this selection, configure whether the switching points of the output cams are to reference the actual position or the position setpoint.
The unit of measurement shown for the position of the output cam corresponds to the unit of measurement of the higher-level technology object.
When a time-based cam is selected as the output cam type, the unit of measurement for the switch-on duration and other times is also indicated. The unit of measurement for output cams is always ms.
Select the type of cam output in the Hardware interface configuration window.
圖片: Hardware interface
Select whether you want to output the switching **s generated at the digital output.
Activate output
Select one of the following two output options for outputting the cam track:
- Output via Timer DQ
For output by Timer DQ, select a cam output in the Output field. The selection box displays all channels that have been configured correctly.
提示 Extending the configuration limitsA maximum of eight timer DQ can be configured at the X142 interface. If the Timer DQ at X142 are not sufficient for your needs, you can increase the configuration limits with time-based IO modules: - ET 200SP distributed I/O system: TM Timer DIDQ 10x24V - ET 200MP distributed I/O system: TM Timer DIDQ 16x24V You can find more information on these systems in . |
提示 Unsupported instructions for the X142 interfaceThe function blocks for the use of time-based IO (TIO instructions) are not supported by the X142 interface. Recommendation: For the timer DQ, use the output cam or cam track technology object. |
- Output by digital output module
For output by a digital output module, select a digital output in the Output field. Only the digital outputs with previously defined PLC tags are displayed for selection.
提示 Output via the X122, X132 or X142 interfaceAlso use the "Output by digital output module" setting in the following cases: - The output occurs at the X142 interface by a DQ instead of a Timer DQ. - The output occurs by a digital output of the X122 or X132 interface (configured ** 39x required) In both cases you must define a PLC tag for the respective I/O address. |
Output deactivated
When output is deactivated, the cam track is evaluated only in the software.
圖片: Activation time
The specified output cam type is indicated at the top of the Activation time configuration window.
For a time shift of the switch-on and switch-off times of the output cams, enter an activation time and a deactivation time.
圖片: Hysteresis
To prevent unwanted changes in the switching state of the output cams of a cam track, enter a hysteresis value.
When using output cams that reference the actual position, it is advisable to enter a hysteresis value (> 0.0).
In addition to the output cam technology object already described, the cam track technology object is also available.
詞條
詞條說明
選電機、驅動器及常問問題SINAMICS V90 分為兩個版本:脈沖序列版本(集成了脈沖,模擬量,USS/MODBUS)和PROFINET通訊版本。SINAMICS V90 PN 版本集成了 PROFINET 接口,可以通過 PROFIdrive 協(xié)議與上位控制器進行通訊。SIMOTICS 1FL6電機有低慣量(高動態(tài)) 帶增量式編碼器2500線或單圈21位**值編碼器、高慣量(高穩(wěn)定)帶增量式編
IP 地址的取值范圍和示例IP 地址的取值范圍IP 地址由四個介于 0 到 255 之間的十進制數字組成,中間以句點分隔。表示法: xxx.yyy.zzz.www實例:141.80.0.16下列地址有特殊意義(*代表數字 0 到 255 之間的任何數字):-?127.*.*.* 回送地址-?0.0.0.0 未*網絡-?255.255.255.255 向所有設備廣播(
PtP 傳輸 (ASCII)說明在“屬性> 常規(guī) > PtP > 中斷選擇”(Properties > General > PtP > Interrupt selection) 中,設置中斷、CPU STOP 的特性以及協(xié)議。 選擇“ASCII”作為協(xié)議。根據所選的協(xié)議類型,區(qū)域導航中的進一步細分會有所不同。對于“ASCII”,有 4 個參數組: 傳輸、末端分隔
打開和關閉參考項目簡介可將項目和本地保存的會話作為參考項目打開。打開參考項目要打開參考項目,請按以下步驟操作:在“視圖”(View) 菜單中,選中“參考項目”(Reference projects) 復選框。“參考項目”(Reference projects) 選項板將顯示在項目樹中。在項目樹的“參考項目”(Reference projects) 選項板中,單擊工具欄中的“打開參考項目”(Open
公司名: 上海騰希電氣技術有限公司
聯系人: 田禮科
電 話: 021-37660026
手 機: 13681875601
微 信: 13681875601
地 址: 上海松江上海市松江區(qū)廣富林路4855弄星月大業(yè)**88號4樓
郵 編:
網 址: shtxjd.cn.b2b168.com
公司名: 上海騰希電氣技術有限公司
聯系人: 田禮科
手 機: 13681875601
電 話: 021-37660026
地 址: 上海松江上海市松江區(qū)廣富林路4855弄星月大業(yè)**88號4樓
郵 編:
網 址: shtxjd.cn.b2b168.com